{"id":45532,"date":"2019-10-17T13:38:59","date_gmt":"2019-10-17T11:38:59","guid":{"rendered":"https:\/\/www.matelco.es\/automatic-sludge-blanket-level-detector\/"},"modified":"2024-07-17T10:43:51","modified_gmt":"2024-07-17T08:43:51","slug":"automatic-sludge-blanket-level-detector","status":"publish","type":"post","link":"https:\/\/www.matelco.es\/en\/automatic-sludge-blanket-level-detector\/","title":{"rendered":"Automatic sludge blanket level detector"},"content":{"rendered":"<p>The automatic sludge blanket level detector is a robust and reliable optical measuring system with no moving parts.<\/p>\n<p>&nbsp;<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-3192\" src=\"https:\/\/www.matelco.es\/wp-content\/uploads\/2019\/10\/detector-nivel-manto-lodos.jpg\" alt=\"\"><\/p>\n<h3>ADVANTAGES<\/h3>\n<p><strong>Optimize energy consumption.<\/strong><br \/>\nAutomation of sludge pumping. Instead of pumping at set times, pump when it is really needed.<\/p>\n<p><strong>Optimize water removal to reduce costly additional processing (belt presses, digesters, centrifuges, etc.)<\/strong><br \/>\nAutomatically maximize the density of the sludge layer, avoiding pumping large volumes of sludge by pumping water unnecessarily.<\/p>\n<p><strong>Maintain the preferred mud depth.<\/strong><br \/>\nAutomating sludge layer control. With this interface level analyzer, overflows and processing problems are avoided.<\/p>\n<p><strong>Reduce pump wear and tear.<\/strong>  Pump only when necessary.<\/p>\n<p><strong>Maximize operator time and energy.<\/strong><br \/>\nIt installs quickly and easily, without the need for calibration. Simplify operation with a durable level measuring instrument.<\/p>\n<p><strong>Reduce the cost of chemical dosing in the DAF or CAF flotation system.<\/strong><br \/>\nOptimize the flocculant precipitate (floc) process setting and coagulant dosage control.<\/p>\n<p>&nbsp;<\/p>\n<h3>APPLICATIONS<\/h3>\n<p>In municipal water treatment plants (WWTP) and municipal and industrial wastewater treatment plants (WWTP).<\/p>\n<ul>\n<li>Primary and secondary clarifiers<\/li>\n<li>Inclined plate clarifiers \/ separators (Lamellars)<\/li>\n<li>Dissolved air flotation (DAF) or cavitation air flotation (CAF) tanks<\/li>\n<li>Tank Decantation \/ Control Decantation.<\/li>\n<li>Extraction of minerals such as iron, zinc, copper&#8230;<\/li>\n<li>Industrial process + wastewater clarification such as in the paper industry, chemical industry&#8230;<\/li>\n<li>Sequential Batch Reactor (SBR)<\/li>\n<li>Sedimentation tanks<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h3>CHARACTERISTICS<\/h3>\n<p>The LED light beam automatically adjusts its intensity to detect sludge coverage and supernatant interface levels in primary or secondary sludge, or in light flocs.<\/p>\n<ul>\n<li>Sludge level interface detection is not distorted by curved tank walls with lamellae<\/li>\n<li>Advanced self-diagnosis<\/li>\n<li>Ultra-high intensity infrared beams<\/li>\n<li>Automatic beam intensity control<\/li>\n<li>Linear output 4 &#8211; 20 mA with slurry interface level depth<\/li>\n<li>High and low mud layer depth setpoint relays<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/www.matelco.es\/contacto\/\">Ask us<\/a> any questions about the operation of this analyzer and our team of experts in water analysis will advise you technically. Send your email from the <a href=\"https:\/\/www.matelco.es\/contacto\/\">contact section<\/a>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The automatic sludge blanket level detector is a robust and reliable optical measuring system with no moving parts. &nbsp; ADVANTAGES Optimize energy consumption. Automation of sludge pumping. Instead of pumping at set times, pump when it is really needed. Optimize water removal to reduce costly additional processing (belt presses, digesters, centrifuges, etc.) Automatically maximize the&hellip;<\/p>\n","protected":false},"author":1,"featured_media":45511,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[622],"tags":[],"class_list":["post-45532","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-wastewater-treatment","category-622","description-off"],"_links":{"self":[{"href":"https:\/\/www.matelco.es\/en\/wp-json\/wp\/v2\/posts\/45532","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.matelco.es\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.matelco.es\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.matelco.es\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.matelco.es\/en\/wp-json\/wp\/v2\/comments?post=45532"}],"version-history":[{"count":0,"href":"https:\/\/www.matelco.es\/en\/wp-json\/wp\/v2\/posts\/45532\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.matelco.es\/en\/wp-json\/wp\/v2\/media\/45511"}],"wp:attachment":[{"href":"https:\/\/www.matelco.es\/en\/wp-json\/wp\/v2\/media?parent=45532"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.matelco.es\/en\/wp-json\/wp\/v2\/categories?post=45532"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.matelco.es\/en\/wp-json\/wp\/v2\/tags?post=45532"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}