{"id":45509,"date":"2021-03-12T15:52:05","date_gmt":"2021-03-12T14:52:05","guid":{"rendered":"https:\/\/www.matelco.es\/control-of-organic-load-in-drinking-water-part-ii\/"},"modified":"2024-07-17T10:43:46","modified_gmt":"2024-07-17T08:43:46","slug":"control-of-organic-load-in-drinking-water-part-ii","status":"publish","type":"post","link":"https:\/\/www.matelco.es\/en\/control-of-organic-load-in-drinking-water-part-ii\/","title":{"rendered":"Control of organic load in drinking water &#8211; Part II"},"content":{"rendered":"<h3>Objectives to be developed in this article:<\/h3>\n<ol>\n<li>Improved efficiency of chemical addition in the coagulation-flocculation process.<\/li>\n<li>Early detection of activated carbon filter saturation.<\/li>\n<li>Decreased energy consumption in UV disinfection control and increased lamp life.<\/li>\n<li>Water storage: ensure drinking water quality by continuously measuring organic contaminants prior to distribution.<\/li>\n<\/ol>\n<p>&nbsp;<\/p>\n<p><strong>Let&#8217;s remember where we can measure the organic load in a drinking water plant<\/strong><\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-3472\" src=\"https:\/\/www.matelco.es\/wp-content\/uploads\/2021\/03\/medida-ami-sac254.jpg\" alt=\"measure-ami-sac254\"><\/p>\n<p>The <a href=\"https:\/\/www.matelco.es\/control-de-la-carga-organica-en-agua-potable-primera-parte\/\" target=\"_blank\" rel=\"noopener\">first part<\/a> of the water intake was treated as follows<\/p>\n<p>&nbsp;<\/p>\n<h3>COAGULATION-FLOCCULATION-SEDIMENTATION<\/h3>\n<p>Coagulation \/ flocculation followed by sedimentation \/ filtration is a process to remove suspended solids of organic and inorganic nature from drinking water.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-3475\" src=\"https:\/\/www.matelco.es\/wp-content\/uploads\/2021\/03\/coagulacion-floculacion-sedimentacion.jpg\" alt=\"coagulation-flocculation-sedimentation\"><\/p>\n<ul>\n<li>Monitoring of the effective removal of natural organic matter (NOM) in the coagulation and sedimentation process.<\/li>\n<li>Improved process monitoring, improving efficiency and effectiveness of chemical addition and energy consumption.<\/li>\n<\/ul>\n<p><span style=\"color: #ff0000;\">Microorganisms + NOM + disinfectant &#8212;&#8212;&#8212;&gt; Microorganisms destroyed + disinfection by-products (DPB), associated with various types of cancer. Limited in RD 140\/2003.<\/span><\/p>\n<p>The following graph shows the formation of the main and most elementary of these by-products, chloroform, as a function of the chlorine applied and contact time, in a given water<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-3478\" src=\"https:\/\/www.matelco.es\/wp-content\/uploads\/2021\/03\/cloroformo-cloro-aplicado.jpg\" alt=\"chloroform-chloroform-applied\"><\/p>\n<p>&nbsp;<\/p>\n<h3>FILTRATION<\/h3>\n<ul>\n<li>Monitoring of the effectiveness of the activated carbon filtration process allowing improved forecasting of the extent of filter saturation, thus minimizing unexpected downtime.<\/li>\n<li>Measurement before and after the activated carbon filter.<\/li>\n<\/ul>\n<p>Tendency to decrease the difference between input and output.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-3484\" src=\"https:\/\/www.matelco.es\/wp-content\/uploads\/2021\/03\/evolucion-filtro-carbono-activo.jpg\" alt=\"evolution-filter-carbon-active\"><\/p>\n<p style=\"text-align: center;\">Correct levels of SAC 254nm at the outlet of the active carbon filter<\/p>\n<p>&nbsp;<\/p>\n<h3>UV DISINFECTION<\/h3>\n<p>Verify and optimize correct UV disinfection.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-3487\" src=\"https:\/\/www.matelco.es\/wp-content\/uploads\/2021\/03\/desinfeccion-uv.jpg\" alt=\"\"><\/p>\n<ul>\n<li>Process control, enhanced by monitoring the effectiveness and efficiency of UV disinfection.<\/li>\n<li>UV light with wavelength &lt;280nm destroys the DNA of microorganisms.<\/li>\n<li>The disinfection efficiency is given by the formula:<br \/>\nUV intensity (expressed as energy per unit area) x resistance time.<br \/>\nThe appropriate UV dosage for each application must take into account water quality, arc tube aging, industry specifications and microbiological standards.<\/li>\n<li>Decreased energy consumption for UV disinfection control and increased lamp life<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h3>WATER STORAGE<\/h3>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-3469\" src=\"https:\/\/www.matelco.es\/wp-content\/uploads\/2021\/03\/almacenamiento-agua.jpg\" alt=\"storage-water\"><\/p>\n<ul>\n<li>Ensures drinking water quality by continuously measuring organic contaminants prior to distribution.<\/li>\n<li>Control of the organic load is especially important if chlorine is used as a disinfectant, as it reacts with organic substances and forms disinfection by-products that are potentially carcinogenic, such as trihalomethanes (THMs) and haloacetic acids (HAAs).<\/li>\n<\/ul>\n<p>Correlation with various carbon-based parameters is also possible, provided that the composition of water pollutants remains constant.<\/p>\n<p>Common correlations:<\/p>\n<ul>\n<li>COD chemical oxygen demand<\/li>\n<li>TOC: total organic carbon<\/li>\n<li>BOD. biochemical oxygen demand<\/li>\n<\/ul>\n<p><span style=\"color: #3366ff;\"><strong>AMI SAC 254: GUARANTEES THE QUALITY OF DRINKING WATER WITH GREATER SAFETY<\/strong><\/span><\/p>\n<ol>\n<li>In surface water, the natural organic load can be very variable, so online detection can be very important to optimize treatment and ensure consistently high water quality.<\/li>\n<li>Disinfection by-products prevention and abatement (SPD)<\/li>\n<li>Optimization of flocculant and\/or coagulant consumption.<\/li>\n<li>Checking the operation of decanters.<\/li>\n<li>Status trends of activated carbon filters.<\/li>\n<li>In case of using UV disinfection, analyze the SAC 254 to know the status of disinfection.<\/li>\n<\/ol>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-3490\" src=\"https:\/\/www.matelco.es\/wp-content\/uploads\/2021\/03\/contadores.jpg\" alt=\"\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Objectives to be developed in this article: Improved efficiency of chemical addition in the coagulation-flocculation process. Early detection of activated carbon filter saturation. Decreased energy consumption in UV disinfection control and increased lamp life. Water storage: ensure drinking water quality by continuously measuring organic contaminants prior to distribution. &nbsp; Let&#8217;s remember where we can measure&hellip;<\/p>\n","protected":false},"author":1,"featured_media":45501,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[616],"tags":[],"class_list":["post-45509","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-drinking-water-treatment","category-616","description-off"],"_links":{"self":[{"href":"https:\/\/www.matelco.es\/en\/wp-json\/wp\/v2\/posts\/45509","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.matelco.es\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.matelco.es\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.matelco.es\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.matelco.es\/en\/wp-json\/wp\/v2\/comments?post=45509"}],"version-history":[{"count":0,"href":"https:\/\/www.matelco.es\/en\/wp-json\/wp\/v2\/posts\/45509\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.matelco.es\/en\/wp-json\/wp\/v2\/media\/45501"}],"wp:attachment":[{"href":"https:\/\/www.matelco.es\/en\/wp-json\/wp\/v2\/media?parent=45509"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.matelco.es\/en\/wp-json\/wp\/v2\/categories?post=45509"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.matelco.es\/en\/wp-json\/wp\/v2\/tags?post=45509"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}